INFORMATIONS MEDICALES SUR LE FIBROSCAN

 


Copyright © 2003 Echosens

 

Le FibroScan quantifie de façon instantanée et totalement non invasive la fibrose du foie.

 

Principe :

Le principe utilisé est simple : plus le foie est dur, plus la fibrose est importante.


Copyright © 2003 Echosens

 

Le FibroScan mesure la dureté du foie et donne un résultat en kPa, l'unité de mesure de la dureté.
Cette relation entre la dureté du foie et le degré de fibrose est à rapprocher de la palpation du médecin. Une étude clinique préliminaire, qui sera publiée cet automne dans la revue « Ultrasound in Medicine and Biology », valide cette relation (cf site www.echosens.com ). D'autres études cliniques de plus grande envergure sont en cours.

Pour mesurer la dureté du foie, le FibroScan utilise une nouvelle technologie brevetée, l'élastométrie impulsionnelle. Celle-ci consiste à engendrer une petite vibration à la surface de la peau qui va se propager jusque dans le foie. A l'aide d'ultrasons, on en mesure la vitesse de déplacement. Plus cette vibration se déplace rapidement, plus le foie est dur.

 


Sonde -
Copyright © 2003 Echosens

 


Le FibroScan semble être un instrument très fiable :
La mesure de la dureté est une mesure quantitative d'un paramètre physique concret et précis.
D'autre part, elle est faite directement dans le foie et n'est pas influençable par des conditions extra-hépatiques.


Avantage

Les avantages de l'utilisation du FibroScan sont nombreux :
1. La mesure est entièrement non invasive (pas de prise de sang) et totalement indolore pour le patient.
2. L'examen est très simple et s'apparente à un examen doppler. Il ne prend que 5 minutes.
3. Le résultat de la mesure est connu immédiatement
4. La mesure peut être faite au cours d'un traitement pour évaluer l'impact anti-fibrosant d'une thérapie
5. La mesure peut être faite aussi souvent que nécessaire

Le FibroScan est homologué et commercialisable dès maintenant.



Interface utilisateur -
Copyright © 2003 Echosens

 


Copyright © 2003 Echosens

 


DOCUMENTS SCIENTIFIQUES

Articles :

L. Sandrin, B. Fourquet, J.M. Hasquenoph, S. Yon, C. Fournier, F. Mal, C. Christidis, M. Ziol, B. Poulet, F. Kazemi, M. Beaugrand and R. Palau.
Transient elastography: a new non-invasive method for assessment of hepatic fibrosis. (accepted in Ultrasound in Medicine and Biology)

Abstract -Chronic hepatitis is accompanied by progressive deposit of hepatic fibrosis, which may lead to cirrhosis. Evaluation of liver fibrosis is thus of great clinical interest and up to now is assessed with liver biopsy. This work aims to evaluate a new non-invasive device to quantify liver fibrosis: the shear elasticity probe or FibroScan®. This device is based on one-dimensional transient elastography, a technique that uses both ultrasound (5 MHz) and low-frequency (50 Hz) elastic waves, which propagation velocity is directly related to elasticity. The intra and inter-operator reproducibility of the technique as well as its ability to quantify liver fibrosis were evaluated in 106 patients with HCV chronic hepatitis. Liver elasticity measurements are reproducible (standardized coefficient of variation: 3%), operator-independent and well correlated (r = 0.81, p << 0.0001) to fibrosis grade (METAVIR). The areas under the ROC curves are 0.88 and 0.99 for the diagnosis of patients with significant fibrosis (>= F2) and with cirrhosis (= F4) respectively.

L. Sandrin, M. Tanter, J.L. Gennisson, S. Catheline and M. Fink.
Shear elasticity probe for soft tissues with 1-D transient elastography.
IEEE UFFC 2002;49:436-446.

Abstract -Important tissue parameters such as elasticity can be deduced from the study of the propagation of low frequency shear waves. A new method for measuring the shear velocity in soft tissues is presented in this paper. Unlike conventional transient elastography in which the ultrasonic transducer and the low frequency vibrator are two separated parts, the new method relies on a probe that associates the vibrator and the transducer, which is built on the axis of the vibrator. This setup is easy to use. The low frequency shear wave is driven by the transducer itself that acts as a piston while it is used in pulse echo mode to acquire ultrasonic lines. The results obtained with the new method are in good agreement with those obtained with the conventional one.

Conférences :

M. Beaugrand, M. Ziol, L. Sandrin, C. Fournier, A. Biaggi-Frassati, B. Poulet,
J.C. Trinchet, F. Mal, C. Christidis, F. Kazemi, V. Grando, N. Ganne and R. Palau.
Liver elasticity measurements by ultrasonic transient elastography: a new non-invasive method
for assessment of liver fibrosis in chronic viral hepatitis.

54th Annual Meeting of the American Association for the Study of Liver Diseases. United-State, Boston, October 24 ­ 28, 2003.

M. Beaugrand, R. Palau, F. Mal, C. Christidis, M. Ziol, L. Sandrin, C. Fournier
and B. Fourquet.
Transient elastrography a new non invasive method for assessment of liver fibrosis:
results in patients with HCV chronic hepatitis.

38th Annual Meeting of the European Association for the Study of Liver. Switzerland, Geneva, July 3 ­ 6, 2003.

C. Christidis, L. Sandrin, R. Palau, M. Ziol, B. Fourquet, F. Mal, P. Callard, M. Beaugrand, C. Fournier, B. Gayet.
L'élasticité du foie est-elle un reflet de la fibrose hépatique ou peut-on évaluer la fibrose par une méthode non invasive ? Résultat d'une étude pilote par élastographie.
Journées francophones de pathologie digestive, 27ème édition. France, Paris, March 29 ­ April 2, 2003.

M. Beaugrand
Elastometry: an alternative to liver biopsy for the evaluation of hepatic fibrosis in HCV patients.
Highly Advanced Medical Technologies. Japan, Tokyo, February 14, 2003.

R. Palau
The experience of a radiologist with the elastometer. An application of transient elastography.
Highly Advanced Medical Technologies. Japan, Tokyo, February 14, 2003.

R. Palau, L. Sandrin, J.M. Hasquenoph, S. Yon, C. Fournier and B. Fourquet.
Noninvasive Tissue Elasticity Probe
Radiological Society of North America. 88th Scientific Assembly and Annual Meeting. USA, Chicago, December 1-6, 2002.

C. Christidis, F. Mal, M. Beaugrand, N. Bouzar, C. Strauss, G, Seguin, S. Lenoir,
L. Fontanelle, M. Zins, R. Palau, L. Sandrin, C. Fournier and B. Fourquet.
Noninvasive Evaluation of the Hepatic Fibrosis Using Transient Elastography.
Radiological Society of North America. 88th Scientific Assembly and Annual Meeting. USA, Chicago, December 1-6, 2002.

 

Sites internet :

Pour plus de renseignements sur la technologie et la société EchoSens : Cliquez ici

 

Adresse de la société :

Le FibroScan est produit par EchoSens, société française située à Paris. Tél 01 58 65 00 77 Fax : 01 58 65 00 84

 



 